©ALL CONTENT OF THIS WEBSITE IS COPYRIGHTED AND CANNOT BE REPRODUCED WITHOUT THE ADMINISTRATORS CONSENT 2003-2020



High Mg per ML Roids, What you need to know

tee

AnaSCI VET
Feb 6, 2004
4,130
0
0
USA
High Mg per ML Roids, What you need to know

--------------------------------------------------------------------------------

1. Most hormones have a pretty low solubility in oil.
2. The primary ways to increase solubility are to
A) add solvent (BA or EA).
B) Add an ester to the hormone. The longer the ester the more hormone will fit in the oil at a certain mg per ml ratio. Conversely, the weight of the ester is also factored in the total mg per ml ratio, so while you can fit more hormone in, you are getting less actual hormone than the mg amount implies.

Here are some examples:

Ester actual mg/100mg dose
test no ester 100
tren acetate 87
test prop 83
test enanth 72
test cyp 70
test undecan 63
nand phenyl 67
nand deca 64

This means that if your test cyp says 200 mgs per ml you get an actual 140 mgs of test. The rest of the weight is the weight of the ester. If that sounds like a bad deal you need to understand that test no ester is VERY insoluble in oil without going to very high mg per ml solvent concentrations.

This brings up the next point; PAIN!

Why do some shots hurt? There are two primary reasons. One, the solvent ratio is too high. Anything over about 10% starts to hurt. BA and EA are VERY inflammatory to the tissues. That’s why you want ONLY enough to help your oil hold more gear but not so much that it causes inflammation.

The second reason is that the gear crystallizes in the depot. This is precisely why water-based suspensions feel like hammer blows. The water is absorbed FAST, leaving the gear to crystallize in the tissues = PAIN.
Even gear in oil can do this, here is how it works. If you use a low ester weight attached to your gear and make the mg per ml ratio SIGNIFICANTLY higher than the oil will hold on it's own, what happens is the body absorbs the solvent faster than the oil/gear and the gear falls out of the solution and crystallizes in the depot and WHAM, it hurts like hell. An optimum solution has just enough solvent to get more gear into solution than you could otherwise, but not so much that what I just stated happens. When the ratios are correct the gear holds in the solution UNTIL the whole depot is absorbed and very little or no pain is felt. Just to end this misconception once and for all IT IS NOT THE VOLUME OF THE OIL THAT CAUSES THE PAIN, IT IS ONE OF THE CONDITIONS STATED ABOVE. You can shoot 5 cc's of sterile oil and never know you took a shot. It IS NOT HOW MUCH OIL YOU SHOOT! So why does everyone search for super high mg per ml ratio gear like it's the damn holy grail???

What is too high? Well the length of the ester is really what determines that but most of us here know the gear that hurts and know we know why. All tests over 250 mgs per ml hurt, and actually most of the 250 mg tests hurt too. SOOOO many people want there tren at 150-200 mgs per ml. Tren acetate should be at about what?? 75 mgs per ml. That is why all the kits are
designed this way. Do you really think it's cheaper for the kit producers to add MORE oil to their kits instead of less? One other quick note. Oil is used
because it SLOWS absorption. THIS IS PRECISELY WHAT YOU WANT IN A STEROID SHOT! Less oil does not promote the steady state hormone levels achieved with more oil
 

gregdiesel

AnaSCI's Ivan Drago
Apr 3, 2005
534
0
0
makes alot of sense, thx. The reason I prefer high mg/ml doses is b/c I run out of room to shoot it! 250mg/ml Deca is more practical for me for that reason.
 

gregdiesel

AnaSCI's Ivan Drago
Apr 3, 2005
534
0
0
Yeah that would be nice... I wouldn't be able to sit or lay down for a week, then it would be time for the next shot lol
 
P

pincrusher

Guest
SuperFly said:
I wish they could come out with a "Test 1000".
the highest i ever went with test was a 500mg/ml product from black label, and it hurt like hell. after that i said fruck it to high mg/ml dosages and just worked on finding more injection sites for all my shots.